Submit a Question
Frequently Asked Questions
What is unique about the Easylite Integrated Lighting System?
How much do your ballasts cost?
Why don’t your controls require line voltage?
What is a controlled lighting zone?
What types of ballasts do you have?
Can you control incandescent lamps as well?
How does your system handle peak demand load shedding?
Is the Easylite ILS an open system?
Are your ballasts individually addressable?
Q: What is unique about the Easylite Integrated Lighting System?
A: First, that it is an integrated system, which means the ballasts provide the power to our system controls (i.e. the power is integrated). This capability dramatically reduces the cost of installing a controlled lighting system since you don’t need to add the conduit, wire, time and labor to power your control network.
Return to top
Q: How much do your ballasts cost?
A: In a controlled lighting system the cost of the ballasts is just one of the factors that will add into the overall installed system cost. The total installed cost (ballasts, controls, installation, software, etc…) is the more important figure to manage and to compare the benefits of the lighting system for payback and ROI analysis. To learn more regarding our pricing and system costs, please contact us directly.
Return to top
Q: Why don’t your controls require line voltage?
A: All of our controls are powered with low voltage and this voltage is provided directly from our ballasts. This eliminates the need and cost of circuiting line voltage for lighting controls.
Return to top
Q: What is a controlled lighting zone?
A: A controlled lighting zone is a number of ballasts (1 to 250) which are networked together with our low voltage control cables which all respond to the same lighting control(s).
Return to top
Q: What types of ballasts do you have?
A: Easylite has several dimming fluorescent ballasts which support T8, T5 HO and T5 lamps. Although we don’t manufacture CFL or incandescent lamps, we can control these fixtures with our system.
Return to top
Q: Can you control incandescent lamps as well?
A: Yes, although we don’t manufacture CFL or incandescent lamps, we can control these fixtures with our system.
Return to top
Q: How does your system handle peak demand load shedding?
A: The Easylite ILS provides several methods for shedding peak demand. These include:
- Time of Day (TOD) scheduling to reduce lighting load during peak hours
- Interfacing directly with a demand meter and responding to its kyz output
- Manually performing zone or global overrides to reduce lighting load
Return to top
Q: Is the Easylite ILS an open system?
A: No and Yes. The Easylite ILS control scheme is based on a patented technology which enables our system to provide control power directly from the ballast instead of line voltage. Due to the patent, this aspect of the system is not open. However, Easylite recognizes the benefits and advantages of open systems, particularly with regard to facility management integration.
Return to top
Q: Are your ballasts individually addressable?
A: No and Yes. In the Easylite ILS, zones are addressed (using our Address-a-lite module) instead of individual ballasts. Each zone can contain between 1 to 250 ballasts – therefore, zones of one ballast can be designed enabling individual ballast/fixture control.
Return to top